Abstract:
Objective
To estimate the value of open repair of peristomal hernia by using GORE-TEX Dual Mesh.
Methods
From Jan.2003 to Jan.2008,50 patients with peristomal hernia treated by open peristomal hernia repair with GORE-TEX Dual Mesh at our hospital were analyzed retrospectively. Operative time,post-operative complications, post-operative hospitalization and recurrence of hernia were studied.
Results
Open mesh peristomal hernia repair was successfully performed in 50 patients. The operative time was 80(60-100)min.Post-operative hospital stay was 7(5-9)d.Two patients complained of delayed incision and one patient had seroma,which was cured by needle aspiration and physical examination. No erosion and urine leakage occurred postoperatively.No recurrence was observed in all patients during follow-up.
Conclusion
Open repair ofperistomalhernia by using GORE-TEX Dual Mesh is safe and effective..
Key words:
Hernia,abodomianl,
Reoperation
Ji CUI, Jun XIANG, Shuai HUANG, Yi-hua HUANG, Shi-rong CAI, Mei-jin HUANG, Yu-long HE. Open repair of peristomal hernia by using GORE-TEX Dual Mesh[J]. Chinese Archives of General Surgery(Electronic Edition), 2009, 03(03): 227-229.