Comparison between bioluminescent imaging and small-animal 18F-FDG PET/CT in BALB/c mice with breast cancer

Qiao Su1,(), Ying Lin2, Wenwen Li1, Xueke Qian2, Wuguo Li1, Guangyin Zhao1, Ying Du1   

  1. 1. Laboratory Animal Center, the First Affiliated Hospital, Sun Yat-sen University, Guangzhou 510080, China
    2. Department of Thyroid and Breast Surgery, the First Affiliated Hospital, Sun Yat-sen University, Guangzhou 510080, China
  • Received:2016-06-14 Online:2017-02-01 Published:2017-02-01
  • Contact: Qiao Su
  • About author:
    Corresponding author: Su Qiao, Email:

Abstract:

Objective

To compare the effect of bioluminescent imaging and small animal PET/CT imaging technology in breast cancer mouse model, and to find a suitable molecular imaging method for the evaluation of breast cancer model.

Methods

Luc expressing 4T1 cell was inoculated into the second mammary fat pad on the left side of normal BALB/c mice to establish the tumor models, and then tumor growth was assessed by bioluminescent imaging and small animal PET/CT. PET/CT images were analyzed through IRW (Inveon Research Workplace) to find out region-of-interest.

Results

The procedure of bioluminescent imaging was relatively simpler than small-animal PET/CT. The tumors could be detected by bioluminescent imaging in a short time, and there was high uptake of 18F-FDG in the tumor with small-animal PET/CT. 18F-FDG absorption time was 30-60 min with radiation, and fluorescein potassium salt absorption time was 3-5 min without radiation. Small-animal PET/CT imaging costed 20 min, but bioluminescent imaging just needed 3 min. Resolution of small-animal PET/CT and bioluminescent imaging was <1 mm and 1-10 mm respectively. PET/CT was a 3D imaging, while the bioluminescent imaging was 2D imaging.

Conclusions

Bioluminescent imaging is better in specificity, simplicity in operation, shorter image acquisition time, cheaper, without radioaction, and can detect cell survival state. Small animal PET/CThas the advantage of high resolution, accurate location, three-dimensional image and cell metabolism monitoring.

Key words: Luminescent measurements, Animal PET/CT, Mice, Breast neoplasms